Corrosion control by voltage scanning technique at potential of zero charge/

Corrosion protection at potential of zero charge, Epzc, technique is an effective method to control corrosion with low cost and more environmental friendly. Previously, cathodic protection is used to control corrosion but it consumes more current and potential zero charge method is studied to replac...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autor principal: Malah a/p Suparmaniam (Autor)
Format: Software eBook
Idioma:English
Publicat: Perlis, Malaysia School of Metallurgy Engineering, University Malaysia Perlis 2016
Matèries:
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
LEADER 02543nmm a2200349 i 4500
001 vtls000127519
003 MY-KaKUK
005 20210816101235.0
006 m fq d
007 co cg||||uuuuu
008 161206s2016 my fq d eng d
035 |a (OCoLC)963005466 
035 |a (OCoLC)ocn963005466 
039 9 |a 201612161013  |b RAR  |c 201612131440  |d RAR  |c 201612061509  |d RAR  |c 201611181011  |d RAR  |y 201611180852  |z RAR 
040 |a MYPMP  |b eng  |e rda  |c MYPMP 
049 |a MYPA 
090 0 0 |a TN665  |b B2M236 2016  |d rb 
100 1 |a Malah a/p Suparmaniam  |e author 
245 1 0 |a Corrosion control by voltage scanning technique at potential of zero charge/  |c Malah a/p Suparmaniam 
264 1 |a Perlis, Malaysia  |b School of Metallurgy Engineering, University Malaysia Perlis  |c 2016 
300 |a 1 CD-ROM  |c 12 cm. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a computer disc  |b cd  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
520 |a Corrosion protection at potential of zero charge, Epzc, technique is an effective method to control corrosion with low cost and more environmental friendly. Previously, cathodic protection is used to control corrosion but it consumes more current and potential zero charge method is studied to replace it. Epzc is a new method using small current to mutually neutralize the positive and negative charges electric double layer on metal-solution interface. This method reduces the electric current that need to supply in order to protect steel from corrosion damage. Potentiostat is used to determine voltage scanning and current density in 3.5 wt % of sodium chloride. In this research open circuit potential and Tafel was plotted to identify corrosion potential, Ecorr, and corrosion current density, Icorr, value of mild steel. Identification of PZC current supply, magnitude of voltage scanning towards Ecorr and voltage scan rate for -1 to 0mV was conducted as an experiment to prove it. Overall, it is proven that oxidation reaction was not take place at Epzc. Magnesium as a reactive metal also was tested under Epzc for 168 hours shows the positive result whereby at Epzc, the magnesium takes longer time to be corroded. 
650 0 |a Metallurgy. 
949 |a VIRTUAITEM  |d 30000  |f 1  |x 701  |6 902000541  |a TN665 B2M236 2016 rb 
942 |2 lcc  |c COMPFILE 
994 |a C0  |b MYPMP 
999 |c 99811  |d 99811 
952 |0 0  |1 0  |2 lcc  |4 0  |6 TN0665 B2 M236 02016 RB  |7 0  |9 99123  |a PTSFP  |b PTSFP  |c 8  |d 2021-08-16  |l 0  |o TN665 B2M236 2016 rb  |p 902000541  |r 2021-08-16  |t 1  |w 2021-08-16  |y COMPFILE