Quantitative evaluation of output power degradation rate for PV system in FKE UTeM /

PV solar is the conversion of light into electricity using semiconducting materials. Currently, there are two types of PV module that install at the rooftop FKE which are mono and thin film and this PV system has already been operating for seven years. Performance ratio for that PV systems is the ra...

Fuld beskrivelse

Saved in:
Bibliografiske detaljer
Hovedforfatter: Nurhanani Johari (Author)
Format: Bog
Sprog:English
Udgivet: 2020.
Fag:
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
LEADER 02526pam a2200421 i 4500
001 117867
003 UTeM
005 20201202080430.0
008 201015s2020 my ||||| |||| 00| | eng d
999 |c 117867  |d 117867 
020 |c gift 
040 |a UTeM  |b eng  |c UTeM  |e rda 
090 0 0 |a TK1087  |b .N87 2020 
100 0 |a Nurhanani Johari,  |e author.  |9 167327 
245 1 0 |a Quantitative evaluation of output power degradation rate for PV system in FKE UTeM /  |c Nurhanani Johari. 
264 1 |c 2020. 
300 |a ix, 35 pages :  |b illustrations, charts ;  |c 30 cm +  |e 1 computer disc (12 cm) 
336 |a text  |2 rdacontent 
337 |2 rdamedia  |a unmediated 
338 |2 rdacarrier  |a volume 
347 |a text file  |b PDF  |c 1.03 MB  |2 rda 
500 |a Accompanied by CD : CDR 20959. 
504 |a Reference : pages 34-35. 
520 |a PV solar is the conversion of light into electricity using semiconducting materials. Currently, there are two types of PV module that install at the rooftop FKE which are mono and thin film and this PV system has already been operating for seven years. Performance ratio for that PV systems is the rating between the actual data power output from PV solar divide by theoretical calculation power output. There are three method that are used to predict the future performance ratio which are Linear Regression (LR), Auto Regressive Integrated Moving Average (ARIMA) and Support Vector Machine (SVM). The lowest RMSE from the performance ratio in 2016 is selected and is compared with the actual data of PV output in year 2019. Result from the simulation show that ARIMA method is suitable for Mono system while SVM is suitable for Thin-film. Lastly, linear equation is obtained from the prediction data in 2016 and 2019 to be used in determining the future value of performance ratio.  
650 0 |a Photovoltaic power systems.  |9 260 
650 0 |a Electric power systems.   |9 981 
710 2 |a Universiti Teknikal Malaysia Melaka,  |e issuing body.  |9 558 
720 |a Kyairul Azmi Baharin 
790 |a Faculty of Electrical Engineering 
791 |a Master of Electrical Engineering 
792 |a 2020 
942 |2 lcc  |c THM - A  |k a 
996 |a MENA 
997 |a FKE 
998 0 0 |a rh/151020 
998 0 0 |a rd/201020 
952 |0 0  |1 0  |2 lcc  |4 0  |6 TK1087 N87 02020  |7 0  |9 147324  |a PLHKI  |b UDI  |c 1  |d 2020-10-15  |e UTeM  |o TK1087 .N87 2020  |p 87507952  |r 2020-10-15  |w 2020-10-15  |y THM - A 
952 |0 0  |1 0  |2 lcc  |4 0  |6 CDR20959  |7 0  |9 147325  |a MEDIA  |b UDI  |c 5  |d 2020-10-15  |o CDR 20959  |p 87507953  |r 2020-10-15  |w 2020-10-15  |y CDR - MEA